Welcome to the website of Henan Anhel Medical Equipment Co., Ltd.!

Mobile / WhatsApp
+86-13373785886

主页 > Product > Equipment > Hemodialysis >

Hemodialysis
血液透析制水系统

Hemodialysis water system

China's first three-stage reverse osmosis water treatment equipment More pure water, higher dialysis quality, more comfortable patient experience...

  • Features
  • Specifications

Hemodialysis water system

    China's first three-stage reverse osmosis water treatment equipment

    More pure water, higher dialysis quality, more comfortable patient experience

    Model: Three-stage reverse osmosis: AN-ROIII

    Secondary reverse osmosis: AN-ROII/1 type, AN-ROII2 type, AN-ROII/3 type


    Original technology
     
    *Three-stage reverse osmosis technology
    The first-stage reverse osmosis pure water is subjected to uninterrupted repeated cycle filtration treatment by the second-stage reverse osmosis water to achieve unlimited purification and purification of the reverse osmosis water, and then supplied to the dialysis treatment after the third quarter of reverse osmosis treatment. The actual filtration frequency of reverse osmosis pure water output is greater than the commonly understood three-stage reverse osmosis membrane filtration frequency. Finally realized the output of ultrapure water.
     
    *High concentration water recovery rate
    In the three-stage reverse osmosis system, the recovery rate of the first-stage concentrated water is greater than 85%, and the concentrated water produced by the second and third stages is 100% recovered, enters the balancer and dilutes the raw water, so that the concentration of the raw water is reduced, which is beneficial to further Improve the system's reverse osmosis water quality and extend the service life of the membrane.
     
    *High membrane surface cleaning ability
    There are various levels of concentrated water recovery, and higher water flow is used to wash the membrane surface at all levels in the system, which will not cause waste of water resources.

     

    Features and advantages

    High degree of automation: with automatic operating system, automatic start, automatic protection, automatic cleaning, automatic disinfection and logging functions.

    With automatic timing cycle cleaning function in standby mode, effectively prevent the growth of bacteria.

    It has complete on-line conductivity, hardness (selection), residual chlorine (selection), water quality monitoring, water shortage, pressure, voltage and other safety monitoring and protection and alarm functions.

    The automatic frequency conversion control system (selection) can automatically control the amount of water produced according to the actual water consumption of the user, which is more suitable for clinical applications (such as: emergency single hemodialysis operation, saving electricity and water).

    Intelligent control, remote online monitoring (model selection), automatic recording of operating data, convenient management.

    It has the functions of chemical disinfection and thermal disinfection (optional), disinfection protection function, real-time online monitoring of the disinfection operation status, and verification of the completeness of the disinfection operation. During the disinfection process, if there is a water cut or a power failure, the machine will automatically continue the disinfection process after the power is turned on to ensure the integrity of the disinfection and prevent the residual disinfectant from causing harm to the treatment.

     

    Technical parameter

    Product standard: Comply with the hemodialysis industry standard recently promulgated by the country-YY0793.1-2020 "Technical Requirements for Hemodialysis and Related Therapeutic Water Treatment Equipment Part 1: For Multi-bed Dialysis".


    Product water quality: in line with the national hemodialysis water standard YY0572-2015 and the American AAMI/ASAIO hemodialysis water standard.


    Safety performance: GB 4793.1-2007 "Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use Part 1: General Requirements" GB/T14710-2009 "Environmental Requirements and Test Methods for Medical Electrical Appliances".


    Electromagnetic compatibility: The whole machine meets electromagnetic compatibility requirements to ensure that the equipment is used normally and does not interfere with other equipment in the hospital.


    Equipment structure and composition

    It adopts world-class reverse osmosis membranes, high-pressure pumps, controllers and other components.
    The whole system has no dead space, no dead corner design, and no dead space membrane shell.
    The main engine pipe fittings and valves are made of sanitary 304/316L stainless steel.
    Unique tandem reverse osmosis membrane connection provides a variety of combined water production modes.
    No dead space membrane group, no water tank design closed circuit to prevent secondary pollution.
    There is no dead space and constant pressure water supply in the large circulation of the ward pipeline.